Home

North American Technical Support

 

 

Access Control Panels series B



Controllers AC-215IP-BU AC-225-BU AC-225IP-BU AC-425-BU AC-425IP-BU
Doors (STD/EXP) 2 2/4 2/4 4/8 4/8
Expansion none MD-D02B/IO-84B MD-D02B/IO-84B MD-D04B/IO-84B MD-D04B/IO-84B
Connectivity Ethernet & Serial Serial Ethernet & Serial Serial Ethernet & Se

Expansion Modules MD-D02B MD-D04B MD-IO84B
Compatibility AC-225-BU AC-425-BU AC-225-BU & AC-425-BU
Doors  2 4 0

 

ac-215ipb
AC-215IP-BU    
Doors 2 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 2 Weigand or Clock and Data with tamper and LED.
REX Inputs 2 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 2 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 2 DRY Form C relay contacts rated 5A at 30 VDC
Users 30,000  
Events 20,000 Up to 20,000 events stored on board when not connected to PC
Expansion none No expansion on panel, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS485/TCPIP Max length of drop; RS485 2000' using 22ga STP 120 ohm cable, TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 128 128 timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 90 - 265 VAC A 6' standard NEMA power cord is supplied with the panel, packaged inside the enclosure.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 2.0A @ 13.8 VDC Up to 2A at 13.8 VDC available to power locks.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 14.4" X 10.4" X 3.8"  
Weight 8.4 lbs  
Operating Temperature Range 32°F to 120°F  
ac-225-ipb
AC-225(IP)-BU    
Doors (STD/EXP) 2/4 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports (STD/EXP) 2/4 Weigand or Clock and Data with tamper and LED.
REX Inputs (STD/EXP) 2/4 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs (STD/EXP) 2/4 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs (STD/EXP) 2/4 DRY Form C relay contacts rated 5A at 30 VDC
Users 30,000  
Events 20,000 Up to 20,000 events stored on board when not connected to PC
Expansion MD-D02
1 - MD-D02B 2 door expansion may be added, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS485(/TCPIP on IP model) Max length of drop; RS485 2000' using 22ga STP 120 ohm cable, TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 128 128 timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 90 - 265 VAC A 6' standard NEMA power cord is supplied with the panel, packaged inside the enclosure.
Supply current for readers 500 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 2.0A @ 13.8 VDC Up to 2A at 13.8 VDC available to power locks.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 14.4" X 10.4" X 3.8"  
Weight 8.4 lbs  
Operating Temp Range 32°F to 120°F  
ac-425-ipb
AC-425(IP)-BU  
Doors (STD/EXP) 4/8 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports (STD/EXP) 4/8 Weigand or Clock and Data with tamper and LED.
REX Inputs (STD/EXP) 4/8 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs (STD/EXP) * High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs (STD/EXP) * DRY Form C relay contacts rated 5A at 30 VDC
Users 30,000  
Events 20,000 Up to 20,000 events stored on board when not connected to PC
Expansion MD-D04 1 - MD-D04B 4 door expansion may be added, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS485(/TCPIP on IP model) Max length of drop; RS485 2000' using 22ga STP 120 ohm cable, TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 128 128timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 90 - 265 VAC A 6' standard NEMA power cord is supplied with the panel, packaged inside the enclosure.
Supply current for readers 500 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 2.0A @ 13.8 VDC Up to 2A at 13.8 VDC available to power locks.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 14.4" X 10.4" X 3.8"  
Weight 8.4 lbs  
Operating Temp Range 32°F to 120°F  
* In the 1 reader per door mode there are no door monitor/aux inputs or outputs avaialble.  When operated in the 2 reader per door mode  REX inputs  2 and 4 may be used as door monitor inputs or as AUX inputs and the door relays
md-do2b
MD-D02B    
Doors 2 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 2 Weigand or Clock and Data with tamper and LED.
REX Inputs 2 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 2 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 2 DRY Form C relay contacts rated 5A at 30 VDC
Connectivity Stacking Connector Plugs into AC-225 main board only.
Power Supply Voltage 12 VDC Supplied by AC-225.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Dimensions 3.94 x 2.99 x 1.28 in.  
Operating Temp Range 32°F to 120°F  
md-d04b
MD-D04B    
Doors 4 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 4 Weigand or Clock and Data with tamper and LED.
REX Inputs 4 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 0 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 0 DRY Form C relay contacts rated 5A at 30 VDC
Connectivity Stacking Connector Plugs into AC-425 main board only.
Power Supply Voltage 12 VDC Supplied by AC-425.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Dimensions 4.57 x 2.99 x 0.87 in

 

Operating Temp Range 32°F to 120°F  
md-io84b
MD-IO84B    
Doors 0 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 0 Weigand or Clock and Data with tamper and LED.
REX Inputs 0 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 8 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 4 DRY Form C relay contacts rated 5A at 30 VDC
Connectivity Stacking Connector Plugs into AC-225/425 main board only.
Power Supply Voltage 12 VDC Supplied by AC-225/425.
Supply current for readers 0  
Dimensions

3.93 x 2.98 x 1.28 in

 

Operating Temp Range 32°F to 120°F