Home

North American Technical Support

 

 

Legacy Access Control Panels Discontinued



Controllers AC-215 AC-215IP AC-225 AC-225IP AC-425 AC-425IP AC-825IP
Doors (STD/EXP) 2 2 2/4 2/4 4/8 4/8 4/8
Expansion none none MD-D02/IO-84 MD-D02/IO-84 MD-D04/IO-84 MD-D04/IO-84 D-805
Connectivity Serial Ethernet & Serial Serial Ethernet & Serial Serial Ethernet & Serial Ethernet

Expansion Modules MD-D02 MD-D04 MD-IO84
Compatibility AC-225 AC-425 AC-225 & AC-425
Doors  2 4 0

 

AC-215
AC-215    
Doors 2 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 2 Weigand or Clock and Data with tamper and LED.
REX Inputs 2 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 2 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 2 DRY Form C relay contacts rated 5A at 30 VDC
Users 5,000  
Events 5,000 Up to 5000 events stored on board when not connected to PC
Expansion none No expansion on panel, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS232/RS485 Max length of drop; RS485 2000' using 22ga STP 120 ohm cable.
Timezones 32/8 32 timezones or weekly schedules with 8 segments or events per day
Power Supply Voltage 16.8 VAC @ 40 VA An external transformer is required, one ships with the unit in a separate box.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 1A @ 13.8 VDC Up to 1A at 13.8 VDC available to power locks, requires  connecting a jumper from the PS-14 power supply board to the relays.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 13.2" X 10.4" X 3.4"  
Weight 8.4 lbs  
Operating Temp Range 32°F to 120°F  
AC-215 IP
AC-215IP    
Doors 2 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 2 Weigand or Clock and Data with tamper and LED.
REX Inputs 2 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 2 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 2 DRY Form C relay contacts rated 5A at 30 VDC
Users 30,000  
Events 20,000 Up to 20,000 events stored on board when not connected to PC
Expansion none No expansion on panel, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS232/RS485/TCPIP Max length of drop; RS485 2000' using 22ga STP 120 ohm cable, TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 32/16 32 timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 16.8 VAC @ 40 VA An external transformer is required, one ships with the unit in a separate box.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 1.0A @ 13.8 VDC Up to 1A at 13.8 VDC available to power locks, requires  connecting a jumper from the PS-14 power supply board to the relays.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 13.2" X 10.4" X 3.4"  
Weight 8.4 lbs  
Operating Temperature Range 32°F to 120°F  
AC-225
AC-225(IP)    
Doors (STD/EXP) 2/4 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports (STD/EXP) 2/4 Weigand or Clock and Data with tamper and LED.
REX Inputs (STD/EXP) 2/4 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs (STD/EXP) 2/4 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs (STD/EXP) 2/4 DRY Form C relay contacts rated 5A at 30 VDC
Users 30,000  
Events 20,000 Up to 20,000 events stored on board when not connected to PC
Expansion MD-D02
1 - MD-D02 2 door expansion may be added, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS232/RS485(/TCPIP on IP model) Max length of drop; RS485 2000' using 22ga STP 120 ohm cable, TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 32/16 32 timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 16.8 VAC @ 40 VA An external transformer is required, one ships with the unit in a separate box.
Supply current for readers 500 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 1.5A @ 13.8 VDC Up to 1.5A at 13.8 VDC available to power locks, requires  connecting a jumper from the PS-14 power supply board to the relays.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 13.2" X 10.4" X 3.4"  
Weight 8.4 lbs  
Operating Temp Range 32°F to 120°F  
AC-425
AC-425(IP)    
Doors (STD/EXP) 4/8 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports (STD/EXP) 4/8 Weigand or Clock and Data with tamper and LED.
REX Inputs (STD/EXP) 4/8 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs (STD/EXP) * High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs (STD/EXP) * DRY Form C relay contacts rated 5A at 30 VDC
Users 30,000  
Events 20,000 Up to 20,000 events stored on board when not connected to PC
Expansion MD-D04 1 - MD-D04 4 door expansion may be added, may be networked with up to 32 more panels on an RS-485 network.  AxtraxNG supports up to 32 networks for a maximum of 1023 panels.
Connectivity RS232/RS485(/TCPIP on IP model) Max length of drop; RS485 2000' using 22ga STP 120 ohm cable, TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 32/16 32 timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 16.8 VAC @ 40 VA An external transformer is required, one ships with the unit in a separate box.
Supply current for readers 500 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 1.5A @ 13.8 VDC Up to 1.5A at 13.8 VDC available to power locks, requires  connecting a jumper from the PS-14 power supply board to the relays.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 13.2" X 10.4" X 3.4"  
Weight 8.4 lbs  
Operating Temp Range 32°F to 120°F  
* In the 1 reader per door mode there are no door monitor/aux inputs or outputs avaialble.  When operated in the 2 reader per door mode  REX inputs  2 and 4 may be used as door monitor inputs or as AUX inputs and the door relays
ac825 Shown with optional D-805 expansion installed
AC-825(IP)    
Doors (STD/EXP) 4/8* DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports (STD/EXP) 4/8* Weigand or Clock and Data with tamper and LED.
REX Inputs (STD/EXP) 4/8* High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs (STD/EXP) 6/10* High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs (STD/EXP) 2* DRY Form C relay contacts rated 5A at 30 VDC
Users 60,000  
Events 500,000 Up to 500,000 events stored on board when not connected to PC
Expansion, 1 exp may be installed on base unit, up to 12 exp may be connected via OSDP D-805
R-805
S-805
P-805
D-805 adds 4 doors and readers
R-805 adds 16 form C relay outputs
S-805 adds 16 supervised inputs
P-805 adds 8 form C relay outputs and 16 supervised inputs
Connectivity TCPIP on only TCPIP (ethernet) 330' for CAT5E or CAT 6
Timezones 256 256 timezones or weekly schedules with 16 segments or events per day
Power Supply Voltage 100-240 VAC @ 1.6A A standard 3 prong US power cord is shipped withthe unit in the US and Canada.
Supply current for readers 500 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Supply current for locks 2.5A @ 13.8 VDC Up to 2.5A at 13.8 VDC available to power locks, requires  connecting a jumper from the power supply board to the relays.
Battery backup up to 7AH Charging circuit for OPTIONAL SLA 12V 7AH battery, estimated standby of 3 hrs.
Dimensions 13.6" X 15.9" X 4.0"  
Weight 10.1 lbs  
Operating Temp Range 23°F to 122°F  
* There are 4 Wiegand reader ports on the main board, 2 OSDP readers maybe added to bring hte base board up to 6 readers and doors.
 
MD-D02
MD-D02    
Doors 2 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 2 Weigand or Clock and Data with tamper and LED.
REX Inputs 2 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 2 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 2 DRY Form C relay contacts rated 5A at 30 VDC
Connectivity Stacking Connector Plugs into AC-225 main board only.
Power Supply Voltage 12 VDC Supplied by AC-225.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Dimensions 3.94 x 2.99 x 1.28 in.  
Operating Temp Range 32°F to 120°F  
MD-D04
MD-D04    
Doors 4 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 4 Weigand or Clock and Data with tamper and LED.
REX Inputs 4 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 0 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 0 DRY Form C relay contacts rated 5A at 30 VDC
Connectivity Stacking Connector Plugs into AC-425 main board only.
Power Supply Voltage 12 VDC Supplied by AC-425.
Supply current for readers 300 mA Up to 300 mA at 12VDC available to power readers directly from controller board.
Dimensions 4.57 x 2.99 x 0.87 in

 

Operating Temp Range 32°F to 120°F  
MD-IO84
MD-IO84    
Doors 0 DRY Form C relay contacts rated 5A at 30 VDC.
Reader Ports 0 Weigand or Clock and Data with tamper and LED.
REX Inputs 0 High impeadance supervised, programmable for NO or NC, NO default
AUX/Door Inputs 8 High impeadance supervised, programmable for NO or NC, NC default
AUX Outputs 4 DRY Form C relay contacts rated 5A at 30 VDC
Connectivity Stacking Connector Plugs into AC-225/425 main board only.
Power Supply Voltage 12 VDC Supplied by AC-225/425.
Supply current for readers 0  
Dimensions

3.93 x 2.98 x 1.28 in

 

Operating Temp Range 32°F to 120°F